25.3.6.3 Service Request Output Lines
Each ADC module has eight service request outputs. Four of these service request
outputs (SR[3:0]) are connected to interrupt service request nodes while the remaining
four service request outputs (SR[7:4]) are connected as DMA request line with the DMA
controller of the TC1796 (see
Table 25-18 Service Request Lines of ADC0/ADC1
Module
Service
Request Line
Connected To
Description
ADC0
SR0
ADC0_SRC0
ADC0 Service Request Node 0
SR1
ADC0_SRC1
ADC0 Service Request Node 1
SR2
ADC0_SRC2
ADC0 Service Request Node 2
SR3
ADC0_SRC3
ADC0 Service Request Node 3
SR4
CH02_REQI2
CH12_REQI3
DMA Channel 02 Request Input 2
DMA Channel 12 Request Input 3
SR5
CH03_REQI2
CH13_REQI3
DMA Channel 03 Request Input 2
DMA Channel 13 Request Input 3
SR6
CH10_REQI3
CH14_REQI3
DMA Channel 10 Request Input 3
DMA Channel 14 Request Input 3
SR7
CH11_REQI3
CH15_REQI3
DMA Channel 11 Request Input 3
DMA Channel 15 Request Input 3
ADC1
SR0
ADC1_SRC0
ADC1 Service Request Node 0
SR1
ADC1_SRC1
ADC1 Service Request Node 1
SR2
ADC1_SRC2
ADC1 Service Request Node 2
SR3
ADC1_SRC3
ADC1 Service Request Node 3
SR4
CH02_REQI3
CH12_REQI4
DMA Channel 02 Request Input 3
DMA Channel 12 Request Input 4
SR5
CH03_REQI3
CH13_REQI4
DMA Channel 03 Request Input 3
DMA Channel 13 Request Input 4
SR6
CH10_REQI4
CH14_REQI4
DMA Channel 10 Request Input 4
DMA Channel 14 Request Input 4
SR7
CH11_REQI4
CH15_REQI4
DMA Channel 11 Request Input 4
DMA Channel 15 Request Input 4