TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-209
V2.0, 2007-07
MultiCAN, V2.0
22.9.4.5 External CAN Time Trigger Inputs
The external CAN time trigger inputs ECTT[7:1] can be used as a transmit trigger for a
reference message. In the TC1796, these input lines are connected as shown in
.
22.9.4.6 DMA Request Outputs
The interrupt output lines INT_O0 to INT_O2 of the MultiCAN module can be used as a
DMA requestor and are able to trigger DMA transfers. INT_O[2:0] are connected to the
DMA controller as shown in
Table 22-20 External CAN Time Trigger Inputs
Receive Input
Connected to
From Module
ECTT1
P1.3 / REQ3 Input
Port 1
ECTT2
P7.5 / REQ7 Input
Port 7
ECTT3
Output OUT5
GPTA0
ECTT4
Output IOUT2
External Request Unit (SCU)
ECTT5
Output IOUT3
External Request Unit (SCU)
ECTT6
0
–
ECTT7
0
–
Table 22-21 CAN-to-DMA Request Connections
DMA Channel
Connected to
CAN Interrupt Output
Selected in DMA Controller
by Programming
04
INT_O0
CHCR04.PRSEL = 101
B
05
INT_O0
CHCR05.PRSEL = 101
B
06
INT_O1
CHCR06.PRSEL = 110
B
07
INT_O2
CHCR07.PRSEL = 110
B
15
INT_O3
CHCR15.PRSEL = 101
B