![Infineon Technologies TC1796 Скачать руководство пользователя страница 1401](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371401.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-106
V2.0, 2007-07
MultiCAN, V2.0
The Message Object FIFO/Gateway Pointer Register MOFGPRn contains a set of
message object link pointers used for FIFO and gateway operations.
MOFGPRn (n = 0-127)
Message Object n FIFO/Gateway Pointer Register
(0604
H
+n*20
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
SEL
CUR
rw
rwh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TOP
BOT
rw
rw
Field
Bits
Type Description
BOT
[7:0]
rw
Bottom Pointer
Bit field BOT points to the first element in a FIFO
structure.
TOP
[15:8]
rw
Top Pointer
Bit field TOP points to the last element in a FIFO
structure.
CUR
[23:16] rwh
Current Object Pointer
Bit field CUR points to the actual target object within
a FIFO/Gateway structure.
After a FIFO/gateway operation CUR is updated with
the message number of the next message object in
the list structure (given by PNEXT of the message
control register) until it reaches the FIFO top element
(given by TOP) when it is reset to the bottom element
(given by BOT).
SEL
[31:24] rw
Object Select Pointer
Bit field SEL is the second (software) pointer to
complement the hardware pointer CUR in the FIFO
structure. SEL is used for monitoring purposes (FIFO
interrupt generation).