![Infineon Technologies TC1796 Скачать руководство пользователя страница 1141](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371141.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Asynchronous/Synchronous Serial Interface (ASC)
User’s Manual
19-26
V2.0, 2007-07
ASC, V2.0
Note: When the set and clear bits for an error flag are set at the same time during a
WHBCON write operation (e.g SETPE = CLRPE = 1), the error flag in CON is not
affected.
SETPE
11
w
Set Parity Error Flag
0
B
No effect.
1
B
Bit CON.PE is set.
Bit is always read as 0.
SETFE
12
w
Set Framing Error Flag
0
B
No effect.
1
B
Bit CON.FE is set.
Bit is always read as 0.
SETOE
13
w
Set Overrun Error Flag
0
B
No effect.
1
B
Bit CON.OE is set.
Bit is always read as 0.
0
[3:0],
[7:6],
[31:14]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description