![Infineon Technologies TC1796 Скачать руководство пользователя страница 1192](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371192.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Synchronous Serial Interface (SSC)
User’s Manual
20-35
V2.0, 2007-07
SSC, V2.1
The Error Flag Modification Register EFM is required for clearing or setting the four error
flags which are located in register STAT.
0
[7:4],
[31:13]
r
Reserved
Read as 0; should be written with 0.
EFM
Error Flag Modification Register
(2C
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SET
BE
SET
PE
SET
RE
SET
TE
CLR
BE
CLR
PE
CLR
RE
CLR
TE
0
w
w
w
w
w
w
w
w
r
Field
Bits
Type Description
CLRTE
8
w
Clear Transmit Error Flag
0
B
No effect.
1
B
Bit STAT.TE is cleared.
Bit is always read as 0.
CLRRE
9
w
Clear Receive Error Flag
0
B
No effect.
1
B
Bit STAT.RE is cleared.
Bit is always read as 0.
CLRPE
10
w
Clear Phase Error Flag
0
B
No effect.
1
B
Bit STAT.PE is cleared.
Bit is always read as 0.
CLRBE
11
w
Clear Baud Rate Error Flag
0
B
No effect.
1
B
Bit STAT.BE is cleared.
Bit is always read as 0.
Field
Bits
Type Description