![Infineon Technologies TC1796 Скачать руководство пользователя страница 1268](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371268.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-51
V2.0, 2007-07
MSC, V2.0
RDIE
[15:14]
rw
Receive Data Interrupt Enable
This bit field determines the enable conditions for the
receive data interrupt.
00
B
Interrupt generation disabled.
01
B
An interrupt is generated when data is received
and written into the upstream data registers
UDx (x = 0-3).
10
B
An interrupt is generated as with RDIE = 01
B
but only if the received data is not equal to 00
H
.
11
B
An interrupt is generated when data is received
and written into register UD3.
0
6, 10,
[31:16]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description