![Infineon Technologies TC1796 Скачать руководство пользователя страница 1470](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371470.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-175
V2.0, 2007-07
MultiCAN, V2.0
The Time Trigger Status Register TTSR contains the time trigger status information that
does not lead directly to interrupt events.
TTSR
Time Trigger Status Register
(2C8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
ETR
EV
ETR NIG
0
MSCMAX
0
MSCMIN
r
rh
rh
rh
r
rh
r
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
REC
F
TRA
F
TM
PC
CFG
M
ARB
REF
TRG
EFF EFI
0
SYNCS
MSR
ERRS
rh
rh
rh
rh
rh
rh
rh
rh
r
rh
rh
rh
Field
Bits
Type Description
ERRS
[1:0]
rh
Error State
This bit field indicates the current error severity level.
00
B
No error
01
B
Warning
10
B
Error
11
B
Severe error
MSR
[3:2]
rh
Master-Slave Relation
This bit field indicates the current master to slave
relation of the TTCAN node.
00
B
Master off
01
B
Slave (receiving device)
10
B
Potential time master
11
B
Current time master
SYNCS
[5:4]
rh
Synchronization State
This bit field indicates the current synchronization
state of the TTCAN node.
00
B
Sync off
01
B
Synchronizing
10
B
In gap
11
B
In schedule