![Infineon Technologies TC1796 Скачать руководство пользователя страница 1779](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371779.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-124
V2.0, 2007-07
GPTA, V2.0
Variables
Input, Local, Output variables of the cell (I, L, O)
Global variables
Name x = [0,1] for PDL
k = [0 to 5] for FPC
Short
Name
(*)PDL
Used
(ILO)
Comment
FPCk.Signal_Output.Transition
FPCk.Signal_Output.Level
SOTk
SOLk
I
Transition/Level of signals
coming from FPC
S1.Transition, S1.Level
S2.Transition, S2.Level
S3.Transition, S3.Level
S1T, S1L
S2T, S2L
S3T, S3L
L
Transition/Level of Local FPC
signals
PDLx.Signal_Output1.Transition
PDLx.Signal_Output1.Level
SIT0, SIL0
SIT2, SIL2
O
Transition/Level of Output 1
signal going to DCM0/DCM2
PDLx.Signal_Output2.Transition
PDLx.Signal_Output2.Level
SIT1, SIL1
SIT3, SIL3
O
Transition/Level of Output 2
signal going to DCM1/DCM3
PDLx.Signal_Forward
*F0
*F1
O
Forward signals to be counted
by LTC
PDLx.Signal_Backward
*B0
*B1
O
Backward signals to be
counted by LTC
Name x = [0,1] for PDL
Short
Name
(*)PDL
Size
(bits)
Function
PDLx.Mux
*MUXx
1
Selects PDL speed signal
(instead of FPC feed-through
signal) for output 1
PDLx.Three_Sensors_Enable
*TSEx
1
Selects 3-sensor option and
PDL error signal (instead of
FPC feed-through signal) for
output 2
PDLx.Error
*ERRx
1
Makes it possible for the
software to read PDL error