![Infineon Technologies TC1796 Скачать руководство пользователя страница 1390](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371390.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-95
V2.0, 2007-07
MultiCAN, V2.0
RXUPD
2
rh
Receive Updating
0
B
No receive update ongoing.
1
B
Message identifier, DLC, and data of the
message object are currently updated.
NEWDAT
3
rh
New Data
0
B
No update of the message object n since the
last clearance of the flag.
1
B
Message object n has been updated.
NEWDAT is set by hardware after a received CAN
frame has been stored in message object n.
NEWDAT is cleared by hardware when a CAN
transmission of message object n has been started.
NEWDAT should be set by software after the new
transmit data has been stored in message object n to
prevent the automatic clearing of TXRQ at the end of
an ongoing transmission.
MSGLST
4
rh
Message Lost
0
B
No CAN message is lost.
1
B
A CAN message is lost because NEWDAT has
become set again when it has already been set.
MSGVAL
5
rh
Message Valid
0
B
Message object n is not valid.
1
B
Message object n is valid.
Only a valid message object takes part in CAN
transfers.
Field
Bits
Type Description