![Infineon Technologies TC1796 Скачать руководство пользователя страница 1267](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371267.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-50
V2.0, 2007-07
MSC, V2.0
ECIP
[5:4]
rw
Command Frame Interrupt Node Pointer
ECIP selects the service request output line SRn
(n = 3-0) for the command frame interrupt.
00
B
Service request output SR0 selected
01
B
Service request output SR1 selected
10
B
Service request output SR2 selected
11
B
Service request output SR3 selected
ECIE
7
rw
Command Frame Interrupt Enable
This bit enables the command frame interrupt.
0
B
Interrupt generation disabled.
1
B
Interrupt generation enabled.
TFIP
[9:8]
rw
Time Frame Interrupt Pointer
TFIP selects the service request output line SRn
(n = 3-0) for the time frame interrupt.
00
B
Service request output SR0 selected
01
B
Service request output SR1 selected
10
B
Service request output SR2 selected
11
B
Service request output SR3 selected
TFIE
11
rw
Time Frame Interrupt Enable
This bit enables the time frame interrupt.
0
B
Interrupt generation disabled.
1
B
Interrupt generation enabled.
RDIP
[13:12]
rw
Receive Data Interrupt Pointer
RDIP selects the service request output line SRn
(n = 3-0) for the receive data interrupt.
00
B
Service request output SR0 selected
01
B
Service request output SR1 selected
10
B
Service request output SR2 selected
11
B
Service request output SR3 selected
Field
Bits
Type Description