![Infineon Technologies TC1796 Скачать руководство пользователя страница 1482](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371482.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-187
V2.0, 2007-07
MultiCAN, V2.0
TTERIE
3
rw
Transmit Trigger Error Interrupt Enable
TTERIE enables the transmit trigger error interrupt.
This interrupt is generated when TTIRR.TTOF or
TTIRR.TTUF become set (independent of its current
state).
0
B
Transmit trigger error interrupt is disabled.
1
B
Transmit trigger error interrupt is enabled.
Bit field TTINPR.ERRINP selects the interrupt output
line that becomes activated at this type of interrupt.
WTEIE
6
rw
Watch Trigger Event Interrupt Enable
WREIE enables the watch trigger event interrupt.
This interrupt is generated when TTIRR.IWTE or
TTIRR.WTE become set (independent of its current
state).
0
B
Watch trigger event interrupt is disabled.
1
B
Watch trigger event interrupt is enabled.
Bit field TTINPR.ERRINP selects the interrupt output
line that becomes activated at this type of interrupt.
AWDIE
7
rw
Application Watchdog Interrupt Enable
AWDIE enables the application watchdog interrupt.
This interrupt is generated when TTIRR.AWDERR
becomes set (independent of its current state).
0
B
Application watchdog interrupt is disabled.
1
B
Application watchdog interrupt is enabled.
Bit field TTINPR.ERRINP selects the interrupt output
line that becomes activated at this type of interrupt.
ERRSCIE
8
rw
Error State Change Interrupt Enable
ERRSCIE enables the error state change interrupt.
This interrupt is generated when bit field
TTSR.ERRSC changes its state.
0
B
Error state change interrupt is disabled.
1
B
Error state change interrupt is enabled.
Bit field TTINPR.NOTIFINP selects the interrupt
output line that becomes activated at this type of
interrupt.
Field
Bits
Type Description