TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-29
V2.0, 2007-07
MLI, V2.0
Transmitting Controller
In the transmitting controller, a write operation to a location within a Transfer Window
delivers the address, the data, and the data size to the transmitter and triggers the
following actions in the MLI transmitter.
•
The 16 least significant address bits of the Transfer Window write access are stored
in TPxAOFR.AOFF as write offset address. In case of a an access to a Small
Transfer Window, also 16 bits are stored, but the higher bits are not taken into
account.
•
The data of the write access to the Transfer Window is stored in TPxDATAR.DATA.
•
The data width of the write access to the Transfer Window (8-bit, 16-bit, or 32-bit) is
stored in bit field TPxSTATR.DW.
•
Status flag TRSTATR.DVx (data valid) is set, indicating that the pipe contains valid
data for transmission.
•
If the address prediction method is disabled (TCR.NO = 1), the transmission of a
Write Offset and Data Frame is started as soon as the MLI transmitter is idle, no
higher priority frames are pending, and TREADY = 1.
If the address prediction method is enabled (TCR.NO = 0), a Write Offset and Data
Frame is started only if an address prediction is not possible (indicated by
TPxSTATR.OP = 0). If TPxSTATR.OP = 1, an address prediction is possible in the
MLI transmitter (and the MLI receiver) and an Optimized Write Frame can be started.
The address prediction method used is described on
.
•
Status flag TRSTATR.DVx is cleared by hardware and MLI event status flag
TISR.NFSIx (Normal Frame Sent event in pipe x) is set (and a service request output
is activated if enabled by TIER.NFSIEx = 1) after the Write Frame has been finished
and correctly acknowledged by the MLI receiver.
The number m of offset address bits that are transmitted at a Write Offset and Data
Frame is determined by the size of the Remote Window in the receiving controller that
has been previously initialized by the transmission of a Copy Base Address Frame.
Parameter m is referring to bit field TPxSTATR.BS (and RPxSTATR.BS) and can be in
the range of 1 to 16 bits.