TC1796
Peripheral Units (Vol. 2 of 2)
Fast Analog-to-Digital Converter (FADC)
User’s Manual
26-36
V2.0, 2007-07
FADC, V2.0
Note: The hardware does not check whether the enable bits are set in such a way as to
describe a loop of conversion requests (e.g. 0 triggers 2, 2 triggers 3 and 3 triggers
0, etc.). It is in the responsibility of the user to set these bits in an appropriate way.
EN32
26
rw
Enable Neighbor Channel Trigger 32
This bit enables the neighbor channel trigger for
channel 2 when a conversion of channel 3 is started.
0
B
No action.
1
B
A trigger will be generated.
0
0, [7:4],
9,
[15:12],
18,
[23:20],
[31:27]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description