![Infineon Technologies TC1796 Скачать руководство пользователя страница 398](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437398.webp)
TC1796
System Units (Vol. 1 of 2)
Program Memory Unit
User’s Manual
7-47
V2.0, 2007-07
PMU, V2.0
DFSBER
13
rh
DFLASH Single-Bit Error and Correction
This flag indicates the occurrence of a single-bit error
in the DFLASH that has been corrected. DFSBER is
cleared by a Reset-to-Read command, or by a Clear
Status command, or by any reset operation.
0
B
No error has been detected.
(default after reset)
1
B
A single-bit error in DFLASH has been detected
and corrected.
PFDBER
14
rh
PFLASH Double-Bit Error
This flag indicates the occurrence of a double-bit
error in the PFLASH. PFDBER is cleared by a Reset-
to-Read command, or by a Clear Status command, or
by any reset operation.
0
B
No error has been detected.
(default after reset)
1
B
A double-bit error in PFLASH has been
detected.
DFDBER
15
rh
DFLASH Double-Bit Error
This flag indicates the occurrence of a double-bit
error in the DFLASH. DFDBER is cleared by a Reset-
to-Read command, or by a Clear Status command, or
by any reset operation.
0
B
No error has been detected.
(default after reset)
1
B
A double-bit error in DFLASH has been
detected.
PROIN
16
rh
Protection Installed
This flag indicates whether read or/and write
protection is correctly installed. This bit is updated
only if a modified protection installation is detected at
a reset operation.
0
B
No protection is installed.
1
B
A read or/and write protection is correctly
installed.
Field
Bits
Type Description