TC1796
System Units (Vol. 1 of 2)
On-Chip System Buses and Bus Bridges
User’s Manual
6-49
V2.0, 2007-07
Buses, V2.0
SBCU_DBBOS
SBCU Debug Bus Operation Signals Register
(40
H
)
Reset Value: 0000 0000
H
RBCU_DBBOS
RBCU Debug Bus Operation Signals Register
(40
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
RD
0
WR
0
SVM
OPC
r
rw
r
rw
r
rw
rw
Field
Bits
Type Description
OPC
[3:0]
rw
Opcode for Signal Status Debug Trigger
This bit field determines the type (opcode) of a
FPI Bus transaction for which a signal status debug
trigger event is generated (if enabled by
DBCNTL.ONBOS0 = 1).
0000
B
Trigger on single byte transfer selected
0001
B
Trigger on single half-word transfer
selected
0010
B
Trigger on single word transfer selected
0100
B
Trigger on 2-word block transfer selected
0101
B
Trigger on 4-word block transfer selected
0110
B
Trigger on 8-word block transfer selected
1111
B
Trigger on no operation selected
others
Reserved
SVM
4
rw
SVM Signal for Status Debug Trigger
This bit determines the mode of a FPI Bus
transaction for which a signal status debug trigger
event is generated (if enabled by
DBCNTL.ONBOS1 = 1).
0
B
Trigger on user mode selected
1
B
Trigger on supervisor mode selected