![Infineon Technologies TC1796 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437067.webp)
TC1796
System Units (Vol. 1 of 2)
Introduction
User’s Manual
1-28
V2.0, 2007-07
Intro, V2.0
•
Duty Cycle Measurement (DCM)
– Four independent units
– 0 - 100% margin and time-out handling
–
f
GPTA
maximum resolution
–
f
GPTA
/2 maximum input signal frequency
•
Digital Phase Locked Loop (PLL)
– One unit
– Arbitrary multiplication factor between 1 and 65535
–
f
GPTA
maximum resolution
–
f
GPTA
/2 maximum input signal frequency
•
Clock Distribution Unit (CDU)
– One unit
– Provides eight clock output signals (clock bus):
f
GPTA
, divided
f
GPTA
clocks, FPC1/FPC4 outputs, DCM clock, LTC prescaler clock
Signal Generation Unit
•
Global Timers (GT)
– Two independent units
– Two operating modes (Free-Running Timer and Reload Timer)
– 24-bit data width
–
f
GPTA
maximum resolution
–
f
GPTA
/2 maximum input signal frequency
•
Global Timer Cell (GTC)
– 32 units related to the Global Timers
– Two operating modes (Capture, Compare and Capture after Compare)
– 24-bit data width
–
f
GPTA
maximum resolution
–
f
GPTA
/2 maximum input signal frequency
•
Local Timer Cell (LTC)
– 64 independent units
– Three basic operating modes (Timer, Capture and Compare) for 63 units
– Special compare modes for one unit
– 16-bit data width
–
f
GPTA
maximum resolution
–
f
GPTA
/2 maximum input signal frequency
Interrupt Sharing Unit
•
286 interrupt sources, generating up to 92 service requests.