![Infineon Technologies TC1796 Скачать руководство пользователя страница 1784](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371784.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-129
V2.0, 2007-07
GPTA, V2.0
Variables
Input, Local, Output variables of the cell (I, L, O)
Global variables
Name k = [0 to 3] for DCM
Short
Name
(*)PLL
Used
(ILO)
Comment
DCMk.Signal_Output
SOk
I
Input of the cell from DCM
Pll.Event
*EVE
L
Input selected by the multiplexer
Pll.Signal_Output
*SO
O
Output of the cell
Pll.Signal_Uncomp
*SU
O
Uncompensated output of the cell
Pll.Service_Request_Trigger
*SQT
O
Service request when Counter
reaches zero
Name
Short
Name
(*)PLL
Size
(bits)
Function
Pll.Mux
*MUX
2
Selects the signal input for PLL
Pll.Automatic_End
*AEN
1
Performs the acceleration/
deceleration correction
Pll.Perform_End
*PEN
1
Makes it possible to decrement the
Counter at full speed
Pll.Request_Enable
*REN
1
Allows a request when microtick
counter reaches zero
Pll.Number_Mtick
*MTI
16
Number of microticks per input
signal period
Pll.Counter_Mtick
*CNT
16
Microtick counter
Pll.Step
*STP
16
Step value, to be added to
positive/zero delta register
Pll.Reload_Value
*REV
24
Reload value, to be added to
negative delta register
Pll.Delta
*DTR
25
Delta register