![Infineon Technologies TC1796 Скачать руководство пользователя страница 2026](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554372026.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual
25-95
V2.0, 2007-07
ADC, V2.0
MSS1
Module Service Request Status Register 1
(1D4
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
MSR
AS
MSR
QR
MSR
SY
MSR
T
r
rwh rwh rwh rwh
Field
Bits
Type Description
MSRT
0
rwh
Module Service Request Status for Source Timer
This bit specifies if a timer source service request has
been generated.
0
B
No timer source service request has been
generated.
1
B
A timer source service request has been
generated.
This bit is cleared by writing a 1 to its bit position.
MSRSY
1
rwh
Module Service Request Status for Source
Synchronized Injection
This bit specifies if a synchronized injection source
service request has been generated.
0
B
No Synchronized Injection source service
request has been generated.
1
B
A Synchronized Injection source service request
has been generated.
This bit is cleared by writing a 1 to its bit position.
MSRQR
2
rwh
Module Service Request Status for Source Queue
This bit specifies if a queue source service request has
been generated.
0
B
No queue source service request has been
generated.
1
B
A queue source service request has been
generated.