TC1796
System Units (Vol. 1 of 2)
Peripheral Control Processor (PCP)
User’s Manual
11-55
V2.0, 2007-07
PCP, V2.0
11.10.2
PCP Clock Control Register, PCP_CLC
PCP_CLC
PCP Clock Control Register
(00
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PCG
DIS
0
rw
r
Field
Bits
Type Description
PCGDIS
15
rw
Clock Gating Disable Bit
Allows clock gating to be disabled.
0
B
PCP Internal Clock stops when PCP is idle
(default after reset)
1
B
PCP Internal Clock always runs
0
[14:0],
[31:16]
r
Reserved
Read as 0; should be written with 0.