![Infineon Technologies TC1796 Скачать руководство пользователя страница 805](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437805.webp)
TC1796
System Units (Vol. 1 of 2)
LMB External Bus Unit
User’s Manual
13-27
V2.0, 2007-07
EBU, V2.0
Table 13-11 Programmable Parameters of Regions
Register
Parameter
(Bit/Bit field)
Function
EBU_ADDRSELx
EBU_EMUAS
ALTSEG
Alternate segment of region to be compared to
PLMB address bits [31:28].
BASE
Region base address to be compared with PLMB
address in conjunction with the MASK parameter.
MASK
Address mask for each external region. Specifies
the number of right-most bits in the base address
starting from bit 26.
ALTENAB
Alternate segment comparison enable of a region:
Determines whether or not parameter ALTSEG is
always compared to PLMB address.
REGENAB
Enable bit for each region. A disabled region will
always generate a miss during address
comparison.
EBU_BUSCONx
EBU_EMUBC
AGEN
Region access type: Demultiplexed (asynch.) or
Burst Flash (sync.) access
ENDIAN
Region endian mode: Little- or big-endian access
mode
PORTW
External region data bus width: 16-bit or 32-bit
WRITE
Region write protection: ON or OFF
AALIGN
Region address alignment enable: ON or OFF
EBU_CON
GLOBALCS
Global chip select signal selection: Selects the CSx
chip select lines that generate the internal CSGLB
signal (see
).
EBU_EMUOVL
OVERLAY
Overlay chip select signal selection: Selects the
CSx chip select lines that generate the internal
CSOVL signal (see