![Infineon Technologies TC1796 Скачать руководство пользователя страница 1261](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371261.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-44
V2.0, 2007-07
MSC, V2.0
The Downstream Status Register DSS contains counter bit fields, status bits, and
indicates the number of passive time frames.
DSS
Downstream Status Register
(18
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
CFA DFA
0
DC
r
rh
rh
r
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
NPTF
0
PFC
r
rw
r
rh
Field
Bits
Type Description
PFC
[3:0]
rh
Passive Time Frame Counter
In Data Repetition Mode, this bit field indicates the count
of passive time frames that are currently transmitted. In
Triggered Mode PFC remains at 0000
B
.
0000
B
Data frame is transmitted.
0001
B
First passive time frame is transmitted.
0010
B
Second passive time frame is transmitted.
…
B
…
1111
B
Fifteenth passive time frame is transmitted.
NPTF
[11:8]
rw
Number Of Passive Time Frames
This bit field indicates the number of passive time
frames that are inserted in Data Repetition Mode
between two data frames.
0000
B
No passive time frame inserted.
0001
B
One passive time frame inserted.
0010
B
Two passive time frames inserted.
…
B
…
1111
B
Fifteen passive time frames inserted.
Note: NPTF is buffered in a shadow buffer at the start of