SBCU_CON
SBCU Control Register
(10
H
)
Reset Value: 4009 FFFF
H
RBCU_CON
RBCU Control Register
(10
H
)
Reset Value: 4009 FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
SPC
0
SPE PSE
0
DBG
rw
r
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TOUT
rw
Field
Bits
Type Description
TOUT
[15:0]
rw
BCU Bus Time-Out Value
The bit field determines the number of System
Peripheral Bus time-out cycles. Default after reset is
FFFF
H
(= 65536 bus cycles).
1)
DBG
16
rw
BCU Debug Trace Enable
0
B
BCU debug trace disabled
1
B
BCU debug trace enabled (default after reset)
PSE
18
rw
BCU Power Saving (Automatic Clock Control)
Enable
0
B
BCU power saving disabled (default after reset)
1
B
BCU power saving enabled
SPE
19
rw
BCU Starvation Protection Enable
0
B
BCU starvation protection disabled
1
B
BCU starvation protection enabled (default
after reset)
SPC
[31:24] rw
Starvation Period Control
Determines the sample period for the starvation
counter. Must be larger than the number of masters.
The reset value is 40
H
.
0
17
rw
Reserved
Read as 0 after reset; should be written with 0.