TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-201
V2.0, 2007-07
GPTA, V2.0
GIMEN4,
GIMEN5,
GIMEN6,
GIMEN7
7,
15,
23,
31
rw
Enable Multiplexer Connection
0
B
Input n is not connected to any line.
1
B
Input n is connected to the line defined by
GIMLn and GIMGn.
0
3, 11,
19, 27
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description