TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-46
V2.0, 2007-07
MSC, V2.0
The bit fields of the Downstream Select Data Low Register DSDSL determine the data
source for each bit in shift register SRL.
DSDSL
Downstream Select Data Source Low Register
(24
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
SL15
SL14
SL13
SL12
SL11
SL10
SL9
SL8
rw
rw
rw
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SL7
SL6
SL5
SL4
SL3
SL2
SL1
SL0
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
SLx
(x = 0-15)
[2*x+1:
2*x]
rw
Select Source for SRL
SLx determines which data source is used for the shift
register bit SRL[x] during data frame transmission.
00
B
SRL[x] is taken from data register DD.DDL[x].
01
B
Reserved.
10
B
SRL[x] is taken from the ALTINL input line x.
11
B
SRL[x] is taken from the ALTINL input line x in
inverted state.