DMA, V2.0
The Enable Error Register describes how the DMA controller reacts to errors. It enables
the interrupts for the loss of a transaction request or Move Engine errors.
DMA_EER
DMA Enable Error Register
(020
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
TRLINP
ME1INP
ME0INP
E
ME1
DER
E
ME1
SER
E
ME0
DER
E
ME0
SER
rw
rw
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E
TRL
17
E
TRL
16
E
TRL
15
E
TRL
14
E
TRL
13
E
TRL
12
E
TRL
11
E
TRL
10
E
TRL
07
E
TRL
06
E
TRL
05
E
TRL
04
E
TRL
03
E
TRL
02
E
TRL
01
E
TRL
00
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
ETRL0x
(x = 0-7)
x
rw
Enable Transaction Request Lost for
DMA Channel 0x
This bit enables the generation of an interrupt when the
set condition for ERRSR.TRL0x is detected.
0
B
The interrupt generation for a request lost event
for channel 0x is disabled.
1
B
The interrupt generation for a request lost event
for channel 0x is enabled.
ETRL1x
(x = 0-7)
8+x
rw
Enable Transaction Request Lost for
DMA Channel 1x
This bit enables the generation of an interrupt when the
set condition for ERRSR.TRL1x is detected.
0
B
The interrupt generation for a request lost event
for channel 1x is disabled.
1
B
The interrupt generation for a request lost event
for channel 1x is enabled.
EME0SER
16
rw
Enable Move Engine 0 Source Error
This bit enables the generation of a Move Engine 0
source error interrupt.
0
B
Move Engine 0 source error interrupt is disabled.
1
B
Move Engine 0 source error interrupt is enabled.