11.11.22 MOV, Move Register to Register
MOV
Syntax
MOV Rb, Ra, cc_A
Description
If condition CONDCA is true, then move the contents of
register Ra into register Rb. If CONDCA is false, no operation
is performed.
Operation
if (CONDCA = True) then R[b] = R[a] else NOP
Flags
N, Z