![Infineon Technologies TC1796 Скачать руководство пользователя страница 2084](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554372084.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Fast Analog-to-Digital Converter (FADC)
User’s Manual
26-33
V2.0, 2007-07
FADC, V2.0
SIRQx
(x = 0-3)
24 + x
w
Set Interrupt Request Flag
This bit allows bit CRSR.IRQx to be set by software
(if bit RIRQx is written simultaneously with 0).
0
B
No operation
1
B
Bit CRSR.IRQx is set. An interrupt is
generated if CFGRx.IEN = 1.
SIRQFn
(n = 0-1)
28 + n
w
Set Interrupt Request Flag for Filter n
This bit allows bit CRSR.IRQFn to be set by software
(if bit RIRQFn is written simultaneously with 0).
0
B
No operation
1
B
Bit CRSR.IRQFn is set. An interrupt is
generated if FCRn.IEN = 1.
0
[7:4],
[15:12],
[23:22],
[31:30]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description