The Downstream Control Register DSC is used to control the operation mode and frame
layout of the downstream channel transmission. It also contains the two pending status
bits.
DSC
Downstream Control Register
(14
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
PPD
0
NBC
r
rw
r
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DS
DIS
EN
SEL
H
EN
SEL
L
NDBH
NDBL
DP
CP
TM
rh
rw
rw
rw
rw
rh
rh
rw
Field
Bits
Type Description
TM
0
rw
Transmission Mode
This bit selects the transmission mode of the
downstream channel.
0
B
Triggered Mode selected
1
B
Data Repetition Mode selected
CP
1
rh
Command Pending
This bit is set when the downstream command register
DC is written. CP is cleared when the first bit of the
related command frame is sent out.
DP
2
rh
Data Pending
In Triggered Mode, this bit is set when the set data
pending bit ISC.SDP is set by software. In Data
Repetition Mode, this bit is set by hardware at the last
passive time frame. At the start of the data frame, DP is