TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual
25-67
V2.0, 2007-07
ADC, V2.0
0
[15:14]
r
Reserved
Read as 0; should be written with 0.
TSTAT
Timer Status Register
(1B0
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
TIMER
r
rh
Field
Bits
Type Description
TIMER
[13:0]
rh
Timer Register
This bit field contains the current value of the timer.
0
[31:14] r
Reserved
Read as 0.
Field
Bits
Type Description