Note: When the set and clear bits for an error flag are set at the same time during an
EFM write operation (e.g SETPE = CLRPE = 1), the error flag in STAT is not
affected.
SETTE
12
w
Set Transmit Error Flag
0
B
No effect.
1
B
Bit STAT.TE is set.
Bit is always read as 0.
SETRE
13
w
Set Receive Error Flag
0
B
No effect.
1
B
Bit STAT.RE is set.
Bit is always read as 0.
SETPE
14
w
Set Phase Error Flag
0
B
No effect.
1
B
Bit STAT.PE is set.
Bit is always read as 0.
SETBE
15
w
Set Baud Rate Error Flag
0
B
No effect.
1
B
Bit STAT.BE is set.
Bit is always read as 0.
0
[7:0],
[31:16]
r
Reserved
Read as 0; should be written with 0.