TC1796
System Units (Vol. 1 of 2)
Clock System and Control
User’s Manual
3-35
V2.0, 2007-07
Clock, V2.0
3.3.3.3
Fractional Divider Register
FDR
Fractional Divider Register
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
DIS
CLK
EN
HW
SUS
REQ
SUS
ACK
0
RESULT
rwh
rw
rh
rh
r
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DM
SC
SM
0
STEP
rw
rw
rw
r
rw
Field
Bits
Type Description
STEP
[9:0]
rw
Step Value
In normal divider mode, STEP contains the reload
value for RESULT.
In fractional divider mode, this bit field determines
the 10-bit value that is added to RESULT with each
input clock cycle.
SM
11
rw
Suspend Mode
SM selects between granted or immediate suspend
mode.
0
B
Granted suspend mode selected
1
B
Immediate suspend mode selected