![Infineon Technologies TC1796 Скачать руководство пользователя страница 1247](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371247.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-30
V2.0, 2007-07
MSC, V2.0
21.1.4.2 Upstream Channel
, the MSC upstream channel can be connected to up to eight
SDI[7:0] serial inputs. Bit field OCR.SDISEL selects one out of these input lines (input
signal SDI). If OCR.ILP = 0, SDI is directly connected to the serial receive buffer input
SI. If OCR.ILP = 1, SDI is connected to input SI via an inverter.
Figure 21-22 Upstream Channel Serial Data Input Control
MCA05816
ILP
OCR
SI
SDI
SDI[7:0]
8
SDISEL
OCR
3
1
0