ディジタル出力

取扱説明書

形式

DO-A3

Digital Output

Installation Manual

Type

  DO-A3

To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.

製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

MANUAL NO.  TOBP C730600 41E

YASKAWA 1000-Series Option

安川 

1000

シリーズ オプション

Содержание 1000-Series

Страница 1: ...n Manual Type DO A3 To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance Ensure the end user receives this manual MANUAL NO TOBP C730600 41E...

Страница 2: ...e prior written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high qua...

Страница 3: ...00 Series Option DO A3 Installation Manual 3 Table of Contents 1 PREFACE AND SAFETY 4 2 PRODUCT OVERVIEW 7 3 RECEIVING 8 4 OPTION COMPONENTS 9 5 INSTALLATION PROCEDURE 10 6 RELATED PARAMETERS 23 7 TRO...

Страница 4: ...warranty only as to the quality of its products in conforming to standards and specifications published in the Yaskawa manual NO OTHER WARRANTY EXPRESS OR IMPLIED IS OFFERED Yaskawa assumes no liabili...

Страница 5: ...messages could cause fatal injury or damage products and related equipment and systems Note Indicates supplemental information that is not related to safety messages Option Yaskawa 1000 Series Option...

Страница 6: ...the manual When ordering new copies of the manual contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover DANGER Heed the safety mes...

Страница 7: ...pand the number of available digital outputs to monitor unit run status The option has the following features Six photocoupler outputs 48 V 50 mA or less Two relay outputs 250 Vac 1 A or less 30 Vdc 1...

Страница 8: ...ng model or the option does not function properly Option Package Contents Tools Required for Installation A Phillips screwdriver M3 metric 1 2 U S standard size 1 is required to install the option A s...

Страница 9: ...locks TB1 and TB2 Refer to Table 4 on page 22 for details on TB1 and TB2 terminal functions and signal levels A Connector CN5 D Model number B Installation hole E Ground terminal and installation hole...

Страница 10: ...ed off WARNING Electrical Shock Hazard Do not remove the front covers of the unit while the power is on Failure to comply could result in death or serious injury The diagrams in this section may inclu...

Страница 11: ...uit boards Failure to comply may result in ESD damage to circuitry Never shut the power off while the unit is running or outputting voltage Failure to comply may cause the application to operate incor...

Страница 12: ...anual Properly connect all pins and connectors Failure to comply may prevent proper operation and possibly damage equipment Check wiring to ensure that all connections are correct after installing the...

Страница 13: ...struction manual packaged with the unit for information on wiring and connecting the unit Figure 2 shows an exploded view of the unit with the option and related components for reference Figure 2 Figu...

Страница 14: ...ving the covers DANGER Electrical Shock Hazard Disconnect all power to the unit and wait at least the amount of time specified on the unit front cover safety label After all indicators are off measure...

Страница 15: ...41E 1000 Series Option DO A3 Installation Manual 15 2 Insert the option card B into the CN5 A J CN5 B K or CN5 C L connector located on the unit and fasten it into place using one of the included scre...

Страница 16: ...G Figure 5 Figure 5 Connect the Ground Wire Note 1 The option package includes three ground wires Use the longest wire when plugging the option into connector CN5 C on the unit side Use the next long...

Страница 17: ...ightening torque may cause erroneous operation damage the terminal block or cause a fire NOTICE Heat shrink tubing or electrical tape may be required to ensure that cable shielding does not contact ot...

Страница 18: ...ontrol use stable power supply for the voltage reference source Figure 8 Figure 8 Option Connection Diagram 1 Double check the polarity on the diode when connecting a DC relay 2 Install a surge absorb...

Страница 19: ...r to the outside In these cases cut out the perforated openings on the left side of the unit front cover as shown in Figure 9 A and leave no sharp edges to damage wiring Route the wiring inside the en...

Страница 20: ...ce the digital operator D Figure 10 Figure 10 Replace the Front Covers and Digital Operator Note Take proper precautions when wiring the option so that the front covers will easily fit back onto the u...

Страница 21: ...Table 3 Ferrule Type Terminal Sizes Terminal signal Screw Size Tightening Torque Nxm inxlb Bare Cable Ferrule Type Terminals Wire Type Applicable Gauges mm2 Recomm Gauge mm2 Applicable Gauges mm2 Reco...

Страница 22: ...n assigned to each output See the unit Instruction Manual for directions on setting parameters M1 Contact relay output 1 N O output Max voltage and current 250 Vac 1 A 30 Vdc 1 A M2 M3 Contact relay o...

Страница 23: ...Binary Code Output F5 09 2 Multi Function Output Default when Installed to D1000 TB1 M1 M2 Zero speed During run Determined by F5 07 M3 M4 Speed agree Alarm excluding bb Determined by F5 08 TB2 P1 PC...

Страница 24: ...tact output terminals M1 M2 M3 M4 and photocoupler output terminals P1 through P6 1 When installed to drive Default 0 Range 0 to 1A7 When installed to D1000 Default F Range 0 to 160 F5 02 39A Terminal...

Страница 25: ...60 F5 07 39F Terminal M1 M2 Output Selection When installed to drive Default F Range 0 to 1A7 When installed to D1000 Default F Range 0 to 160 F5 08 3A0 Terminal M3 M4 Output Selection When installed...

Страница 26: ...sible Solution Option at unit port CN5 A was changed during run Turn the power off and check the connectors between the unit and option Digital Operator Display Fault Name oFb01 Option Fault CN5 B Opt...

Страница 27: ...length of wiring under 50 m 164 ft Separate the control wiring to the option main circuit wiring and power lines Interface Circuit Figure 11 Figure 11 Output Interface Circuit Digital Operator Display...

Страница 28: ...llowable voltage current 48 Vdc 50 mA Contact Relay Output 2 outputs independent Maximum allowable voltage current 250 Vac max 1 A 30 Vdc max 1 A Ambient Temperature 10 C to 50 C 14 F to 122 F Humidit...

Страница 29: ...Back cover Revision Address February 2011 Chapters 3 4 5 and 7 Edited for clarity January 2011 Front cover back cover Revision Format July 2010 Back cover Revision Address July 2010 Entire document Ed...

Страница 30: ...w yaskawa com sg YASKAWA ELECTRIC CHINA CO LTD 12F Carlton Bld No 21 HuangHe Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECT...