HV580L Series Frequency Inverter
43
Function
Code
Parameter Name
Setting Range
Default
Property
P4-11
Terminal command mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
0
★
P4-12
Terminal UP/DOWN rate
0.001Hz/s
~
65.535Hz/s
1.00Hz/s
☆
P4-13
VS curve 1 minimum input
0.00V
~
P4-15
0.00V
☆
P4-14
Corresponding setting of VS
curve 1 minimum input
-100.0%
~
+100.0%
0.0%
☆
P4-15
VS curve 1 maximum input
P4-13
~
+10.00V
10.00V
☆
P4-16
Corresponding setting of VS
curve 1 maximum input
-100.0%
~
+100.0%
100.0%
☆
P4-17
VS filter time
0.00s
~
10.00s
0.10s
☆
P4-18
VS curve 2 minimum input
0.00V
~
P4-20
0.00V
☆
P4-19
Corresponding setting of VS
curve 2 minimum input
-100.0%
~
+100.0%
0.0%
☆
P4-20
VS curve 2 maximum input
P4-18
~
+10.00V
10.00V
☆
P4-21
Corresponding setting of VS
curve 2 maximum input
-100.0%
~
+100.0%
100.0%
☆
P4-22
AS filter time
0.00s
~
10.00s
0.10s
☆
P4-23
VS curve 3 minimum input
-10.00V
~
P4-25
-10.00V
☆
P4-24
VS Corresponding setting of VS
curve 3 minimum input
-100.0%
~
+100.0%
-100.0%
☆
P4-25
VS curve 3 maximum input
P4-23
~
+10.00V
10.00V
☆
P4-26
Corresponding setting of VS
curve 3 maximum input
-100.0%
~
+100.0%
100.0%
☆
P4-27
VS2 filter time
0.00s
~
10.00s
0.10s
☆
P4-28
PULSE minimum input
0.00kHz
~
P4-30
0.00kHz
☆
P4-29
Corresponding setting of
pulse minimum input
-100.0%
~
100.0%
0.0%
☆