Function
Code
Parameter Name
Setting Range
Default
Property
P9-40
Current upon 1st fault
-
-
●
P9-41
Bus voltage upon 3rd fault
-
-
●
P9-42
DI status upon 1st fault
-
-
●
P9-43
Output terminal status upon
1st fault
-
-
●
P9-44
Frequency upon 1st fault
-
-
●
P9-47
Fault protection action
selection 1
Unit's digit (Motor overload, Err11)
0: Coast to stop
1: Stop according to the stop mode
2: Continue to run
Ten's digit (Power input phase loss, Err12)
Hundred's digit (Power output phase loss,
Err13)
Thousand's digit (External equipment fault,
Err15)
Ten thousand's digit (Communication fault,
Err16)
00000
☆
P9-48
Fault protection action
selection 2
Unit's digit (Encoder fault, Err20)
0: Coast to stop
Ten's digit (EEPROM read-write fault,
Err21)
0: Coast to stop
1: Stop according to the stop mode
Hundred's digit: reserved
Thousand's digit (Motor overheat, Err25)
Ten thousand's digit (Accumulative running
time reached)
00000
☆