HV580L Series Frequency Inverter
12
2.4 Technical specifications
Figure 2-2 Technical specifications of the HV580L
Item
Specifications
Standard
functions
Maximum
frequency
• Vector control: 0–300 Hz• V/F control: 0–320 Hz
Carrier
Frequency
0.5
–16 kHz
The carrier frequency is automatically adjusted based on the load features.
Input frequency
Resolution
Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
Control mode
• Sensorless flux vector control (SFVC)
• Closed-loop vector control (CLVC)
• Voltage/Frequency (V/F) control
Startup torque
• G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)
• P type: 0.5 Hz/100%
Speed range
1:100 (SVC)
1:1000 (FVC)
Speed stability
Accuracy
±0.5% (SVC)
±0.02% (FVC)
Torque control
Accuracy
±5% (FVC)
Overload
capacity
• G type: 60sor 150% of the rated current, 3s for 180% of the rated current
• P type: 60s for 120% of the rated current, 3s for 150% of the rated current
Torque boost
• Fixed boost• Customized boost 0.1%–30.0%
V/F curve
• Straight-line V/F curve• Multi-point V/F curve
• N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power,square)
V/F separation Two types: complete separation; half separation
Ramp mode
• Straight-line ramp• S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0
–6500.0s
DC braking
DC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0
–36.0s
Braking action current value: 0.0%
–100.0%
JOG control
JOG frequency range: 0.00
–50.00 Hz
JOG acceleration/deceleration time: 0.0
–6500.0s
Onboard
multiple preset
speeds
It implements up to 16 speeds via the simple PLC function or combination
of X terminal states.