HV580L Series Frequency Inverter
73
Function
Code
Parameter Name
Setting Range
Default
Property
A0-03
Torque digital setting in torque
control
-200.0%
~
200.0%
150.0%
☆
A0-05
Forward maximum frequency in
torque control
0.00Hz
~
maximum frequency
50.00Hz
☆
A0-06
Reverse maximum frequency in
torque control
0.00Hz
~
maximum frequency
50.00Hz
☆
A0-07
Acceleration time in torque
control
0.00s
~
65000s
0.00s
☆
A0-08
Deceleration time in torque
control
0.00s
~
65000s
0.00s
☆
Table 5-2 Monitoring Parameters
Function Code
Parameter Name
Min. Unit
Communication
Address
Group C: Standard Monitoring Parameters
C-00
Running frequency (Hz)
0.01Hz
7000H
C-01
Set frequency (Hz)
0.01Hz
7001H
C-02
Bus voltage (V)
0.1V
7002H
C-03
Output voltage (V)
1V
7003H
C-04
Output current (A)
0.01A
7004H
C-05
Output power (kW)
0.1kW
7005H
C-06
Output torque (%)
0.1%
7006H
C-07
X state
1
7007H
C-08
DO state
1
7008H
C-09
VS voltage (V)
0.01V
7009H
C-10
AS voltage (V)/ current (mA)
0.01V/0.01mA
700AH
C-11
VS2 voltage (V)
0.01V
700BH
C-12
Count value
1
700CH
C-13
Length value
1
700DH
C-14
Load speed
1
700EH
C-15
PID setting
1
700FH
C-16
PID feedback
1
7010H