HV580L Series Frequency Inverter
35
Function
Code
Parameter Name
Setting Range
Default
Property
P1-04
Rated motor frequency
0.01 Hz to maximum frequency
Model
dependent
★
P1-05
Rated motor rotational speed 1rpm
~
65535rpm
Model
dependent
★
P1-06
Stator resistance
(asynchronous motor)
0.001
–65.535 Ω (AC drive power ≤ 55
kW)
0.0001
–6.5535 Ω (AC drive power > 55
kW)
Tuned
parameters
★
P1-07
Rotor resistance
(asynchronous motor)
0.001
–65.535 Ω (AC drive power ≤ 55
kW)
0.0001
–6.5535 Ω (AC drive power > 55
kW)
Tuned
parameters
★
P1-08
Leakage inductive reactance
(asynchronous motor)
0.01
–655.35 mH (AC drive power ≤ 55
kW)
0.001
–65.535 mH (AC drive power >
55 kW)
Tuned
parameters
★
P1-09
Mutual inductive reactance
(asynchronous motor)
0.1
–6553.5 mH (AC drive power ≤ 55
kW)
0.01
–-655.35 mH (AC drive power > 55
kW)
Tuned
parameters
★
P1-10
No-load current
(asynchronous motor)
0.01 to P1-
03 (AC drive power ≤ 55 kW)
0.1 to P1-03 (AC drive power > 55 kW)
Tuned
parameters
★
P1-16
Stator resistance
(synchronous motor)
0.001
–65.535 Ω (AC drive power ≤ 55
kW)
0.0001
–6.5535 Ω (AC drive power > 55
kW)
Tuned
parameters
★
P1-17
Shaft D inductance
(synchronous motor)
0.01
–655.35 mH (AC drive power ≤ 55
kW)
0.001
–65.535 mH (AC drive power >
55 kW)
Tuned
parameters
★
P1-18
Shaft Q inductance
(synchronous motor)
0.01
–655.35 mH (AC drive power ≤ 55
kW)
0.001
–65.535 mH (AC drive power >
55 kW)
Tuned
parameters
★