HV580L Series Frequency Inverter
44
Function
Code
Parameter Name
Setting Range
Default
Property
P4-30
PULSE maximum input
P4-28
~
100.00kHz
50.00kHz
☆
P4-31
Corresponding setting of
pulse maximum input
-100.0%
~
100.0%
100.0%
☆
P4-32
PULSE filter time
0.00s
~
10.00s
0.10s
☆
P4-33
VS curve selection
Curve 1 (2 points, see P4-13 to
P4-16)
Curve 2 (2 points, see P4-18 to
P4-21)
Curve 3 (2 points, see P4-23 to
P4-26)
Curve 4 (4 points, see A6-00 to
A6-07)
Curve 5 (4 points, see A6-08 to
A6-15)
Ten's digit
AS curve selection (same as VS)
Hundred's digit
VS2 curve selection (same as
VS)
321
☆
P4-34
Setting for VS less than
minimum input
Unit's digit (Setting for VS less
than minimum input)
0: Minimum value
1: 0.0%
Ten's digit (Setting for AS less
than minimum input)0, 1 (same
as VS)
Hundred's digit (Setting for VS2
less than minimum input)0, 1
(same as VS)
000
☆