HV580L Series Frequency Inverter
109
Figure 6-6 Setting of two-line mode 1
1: Two-line mode 2
In this mode, X1 is RUN enabled terminal, and X2 determines the running direction.
The parameters are set as below:
Function Code
Parameter Name
Value
Function Description
P4-11
Terminal command mode 1
Two-line 2
P4-00
X1 function selection
1
RUN enabled
P4-01
X2 function selection
2
Forward or reverse
direction
Figure 6-7 Setting of two-line mode 2
As shown in the preceding figure, if K1 is ON, the AC drive instructs forward rotation when K2 is OFF, and
instructs reverse rotation when K2 is ON. If K1 is OFF, the AC drive stops.
2: Three-line mode 1
In this mode, X3 is RUN enabled terminal, and the direction is decided by X1 and X2.
The parameters are set as below:
Function Code
Parameter Name
Value
Function Description
P4-11
Terminal command mode 2
Three-line 1