HV580L Series Frequency Inverter
145
P9-19
Bus voltage upon 3rd fault
It displays the bus voltage when the latest fault Occurs.
P9-20
Digital Input status upon 3rd fault
It displays the status of all DI terminals when the latest
fault occurs. The sequence is as follows:
If the X terminal is ON, the setting is 1. If the X terminal
is OFF, the setting is 0. The value is the equivalent
decimal number converted from the X terminal status.
P9-21
Output terminal status
upon 3rd fault
It displays the status of all output terminals when the
latest fault occurs. The sequence is as follows:
If an output terminal is ON, the setting is 1. If the output
terminal is OFF, the setting is 0. The value is the
equivalent decimal number converted from the X
terminal statuses.
P9-22
AC drive status upon 3rd
Fault
Reserved
P9-23
Power-on time upon 3rd
Fault
It displays the present power-on time when the latest
fault occurs.
P9-24
Running time upon 3rd
Fault
It displays the present running time when the latest fault
occurs.
P9-27
Frequency upon 2nd fault
Same as P9-17
~
P9-24
P9-28
Current upon 2nd fault
P9-29
Bus voltage upon 2nd fault
P9-30
X terminal status upon 2nd fault
P9-31
Output terminal status
upon 2nd fault
P9-32
Frequency upon 2nd fault
P9-33
Current upon 2nd fault