HV580L Series Frequency Inverter
37
Function
Code
Parameter Name
Setting Range
Default
Property
P2-08
Vector control over excitation
gain
0
~
200
64
☆
P2-09
Torque upper limit source in
speed control mode
0:Function Code P2-10 Setting
1: VS
2: AS
3: VS2
4: Pulse setting
5: Communication setting
6: MIN(VS,AS)
7: MAX(VS,AS)
1-7 option full scale correspond
P2-10
0
☆
P2-10
Digital setting of torque upper
limit in speed control mode
0.0%
~
200.0%
150.0%
☆
P2-13
Excitation adjustment
proportional gain
0
~
20000
2000
☆
P2-14
Excitation adjustment integral
gain
0
~
20000
1300
☆
P2-15
Torque adjustment proportional
gain
0
~
20000
2000
☆
P2-16
Torque adjustment integral
gain
0
~
20000
1300
☆
P2-17
Speed loop integral property
Unit's digit: integral separation
0: Disabled 1: Enabled
0
☆
P2-18
Field weakening mode of
synchronous motor
0: No field weakening
1: Direct calculation
2: Automatic adjustment
1
☆
P2-19
Field weakening depth of
synchronous motor
50%
~
500%
100%
☆