HV580L Series Frequency Inverter
159
Figure 6-28 Swing frequency control
PB-00
Swing frequency
setting mode
Default
0
Setting range
0
Relative to the central frequency
1
Relative to the maximum frequency
This parameter is used to select the base value of the swing amplitude.
•
0: Relative to the central frequency (P0-07 frequency source selection)
It is variable swing amplitude system. The swing amplitude varies with the central frequency (set frequency).
•
1: Relative to the maximum frequency (P0-10 maximum output frequency)
It is fixed swing amplitude system. The swing amplitude is fixed.
PB-01
Swing frequency
amplitude
Default
0.0%
Setting range
0.0%
~
100.0%
PB-02
Jump frequency
amplitude
Default
0.0%
Setting range
0.0%
~
50.0%
This parameter is used to determine the swing amplitude and jump frequency amplitude.
The swing frequency is limited by the frequency upper limit and frequency lower limit.
• If relative to the central frequency (PB-00 = 0), the actual swing amplitude AW is the calculation result of
P0-07 (Frequency source selection) multiplied by PB-01.
• If relative to the maximum frequency (PB-00 = 1), the actual swing amplitude AW is the calculation result of