background image

Shanghai AMP & MOONS’ Automation Co. Ltd.

No.168 Mingjia Road, Industrial Park North Minhang District,

Shanghai 201107, P.R. China

Tel: 86-21-52634688              Fax: 86-21-62968682

E-mail: [email protected]

  

Web: www.moonsindustries.com

Service Center

+86-400-820-9661

4

Configure the Drive

• 

Apply power to the drive

• 

The software will recognize the drive & display the model 

& firmware version

•  Follow the steps on the ST Configurator screens to set 

up the Motor and Motion & I/O

3

Connect the Power Supply

• 

Using the connector supplied to connect the AC power 

supply per the diagram below. For Line (L) and Neutral 
(N), use 16AWG wire. For Earth Ground (

), use 

14AWG wire.

• 

Care should always be taken when working with high 

voltages.

• 

In regions where the single-phase supply is higher, an 

auto transformer can be used to drop the voltage to the 

correct level.

2

Install the Software

•  Download and install the ST Configurator 

Software from the MOONS’ website.

• 

Launch the software by clicking Start... 

Programs  ... MOONS’  

• 

Connect the drive to the PC using the  

CAT5 Ethernet cable

1

Requirements

You will need these items to set-up the MSSTAC5-2V:

• 

94-265V AC power supply

•  a small flat blade screwdriver for tightening the 

connectors (included)

• 

a PC running Microsoft Windows XP, Vista, or Windows 7

• 

a CAT5 Ethernet  programming cable

Safety Instructions

•  Only qualified personnel should assemble, install, operate, or maintain this equipment.
• 

Read all available documentation before assembly and operation.

• 

It is vital to ensure that all system components are connected to earth ground.

• 

This product contains electrostatically sensitive components that can be damaged by incorrect 

handling.

MSSTAC5-2V

EtherNet Step drive

Quick Set-Up Guide

PLC,Sensor,I/O

 

 

 

 

MSSTAC5-S/Q

PC

AC

Source

TCP/IP

PLC,Sensor,I/O

 

 

 

 

 

 

Stall Detection&Prevention

(

Option

)