HV580L Series Frequency Inverter
67
Function
Code
Parameter Name
Setting Range
Default
Property
PC-16
Simple PLC running mode
0: Stop after the AC drive runs one cycle
1: Keep final values after the AC drive
runs one cycle
2: Repeat after the AC drive runs one
cycle
0
☆
PC-17
Simple PLC retentive selection
Unit's digit (Retentive upon power
failure)
0: No
1: Yes
Ten's digit (Retentive upon stop)
0: No
1: Yes
00
☆
PC-18
Running time of simple PLC
reference 0
0.0s(h)
~
6553.5s(h)
0.0s(h)
☆
PC-19
Acceleration/deceleration time
of simple PLC reference 0
0
~
3
0
☆
PC-20
Running time of simple PLC
reference 1
0.0s(h)
~
6553.5s(h)
0.0s(h)
☆
PC-21
Acceleration/deceleration time
of simple PLC reference 1
0
~
3
0
☆
PC-22
Running time of simple PLC
reference 2
0.0s(h)
~
6553.5s(h)
0s(h)
☆
PC-23
Acceleration/deceleration time
of simple PLC reference 2
0
~
3
0
☆
PC-24
Running time of simple PLC
reference 3
0.0s(h)
~
6553.5s(h)
0.0s(h)
☆
PC-25
Acceleration/deceleration time
of simple PLC reference 3
0
~
3
0
☆
PC-26
Running time of simple PLC
reference 4
0.0s(h)
~
6553.5s(h)
0.0s(h)
☆