HV580L Series Frequency Inverter
127
rated AC drive current.
P6-14 (Stop DC braking time)
This parameter specifies the holding time of DC braking. If it is set to 0, DC braking is cancelled.
Figure 6-13 Stop DC braking process
P6-15
Brake use ratio
Default
100%
Setting Range
0%
~
100%
It is valid only for the AC drive with internal braking unit and used to adjust the duty ratio of the braking unit.
The larger the value of this parameter is, the better the braking result will be. However, too larger value causes
great fluctuation of the AC drive bus voltage during the braking process.
Group P7 Operation Panel and Display
P7-01
MF Key function selection
Default
0
Setting Range
0
MF key disabled
1
Switchover between operation panel control and
remote command control (terminal or communication)