1.
Create New User
The fields on the far right of the screen may be used to enter information for a new user. Each user will
be given a unique
User Name
and may be assigned a unique
Email Address
and
Password
. The access
level selected will be either
Service
or
Operator
. Admin access level may not be created. If the user level
is set to
Operator
, three additional fields will be displayed which are used to select to what degree the
user may control the system. Service users automatically have full access to all three of these options,
so these fields will not display if the access level is set to
Service.
•
Start/ Stop Access
This field contains a drop down list which is used to select whether the user has permission to start
or stop the compressor. It may be set to
No Access, Stop Access, Start and Stop
or
Start and Stop
with Capacity Control Access
. The default option is
Start and Stop with Capacity Control Access
.
•
Set Point Access
This field contains a switch which is used to toggle whether or not the user is permitted to access or
change the control set points of the panel. By default, this option is set to
true.
•
Clear Motor Start Timers
This field contains a switch which is used to toggle whether or not the user is permitted to reset the
built in delay timers before the motor starts. By default, this option is set to
false
. Touching the
Save
User
button below the fields will create a user using the information in the fields and add it to the
table of current users.
Touching the
Save User
button below the fields will create a user using the information in the fields and
add it to the table of current users.
2.
Current Users
This section contains a table displaying all users that may log in to the panel. By default, there are two
users:
Service
and
Operator
, though any custom users added in the manner described above will be dis-
played in the table as well. The table contains three columns; the leftmost containing the name of the
user, the middle containing the access level and the rightmost containing a checkbox which is used to
select a user to be edited or removed. The rows corresponding to the two default users do not contain
the checkbox in the leftmost column because they may not be modified or removed. When the checkbox
corresponding to a user is selected, the fields used to create a user will automatically be filled in with the
corresponding information. This will also enable the
Save User
and
Delete User
buttons. Any changes
made to a custom user may be confirmed by touching the
Save User
button. Touching the
Delete User
button will remove the selected user from the table entirely. Only custom users may be deleted or have
their access level modified.
3.
User Timeout
This section is used to select whether the panel will automatically log a user out after a period of inactiv-
ity. User timeout is not set by default, and must be enabled with the
Timeout Enabled
switch shown to
the right of the screen. Toggling the switch on will enable the field shown below it.
•
User Access Timeout
This field contains a drop down list which is used to select the amount of time the panel must remain
idle before the current user is logged out.
Instruction Manual | GEA Omni™
Control panel
User interface
Panel Settings
GEA Refrigeration North America, Inc. | E_806550_2 | Generated 12.01.2016
99