3.1.3
Variable Vi
Parameter
Units
Minimum
Maximum
Default
Vi Operating Mode
Selection – See Description
Vi Dead Band
Percent
2.0 %
100.0 %
2.0 %
Vi Load-Unload Timer
Seconds
1 s
10 s
1 s
Manual Vi Control Vi Setting
Numeric Entry – See Description
Volume Slide Adjustment Factor
Percent
-100 %
100 %
0 %
Low-Medium Vi Transfer Point
Vi
0.0 Vi
10.0 Vi
0.0 Vi
Low-Medium Vi Transfer Dead
Band
Vi
0.0 Vi
10.0 Vi
0.0 Vi
Medium-High Vi Transfer Point
Vi
0.0 Vi
10.0 Vi
0.0 Vi
Medium-High Vi Transfer Dead
Band
Vi
0.0 Vi
10.0 Vi
0.0 Vi
Stepped Manual Vi Control Setting
Selection – See Description
1.
Vi Operating Mode
This parameter is used to select the means by which the compressor will control its
Vi
. This parameter will
only be visible if the
Vi Mode
option in the
Compressor Configuration
is set to
Continuous Variable
. The
options are:
•
Auto
In this mode, the compressor will adjust its Vi based on a calculated optimal Vi position.
•
Manual
In this mode, the compressor will adjust its Vi based on a user selected value.
2.
Vi Deadband
This parameter is used to define a range above and below the optimum Vi point or the manual Vi setting
within which no Vi adjustments will be made. This parameter will only be visible if the
Vi Mode
option in the
Compressor Configuration
is set to
Continuous Variable
. The value is measure in either percent or as a unit
less value depending on the type of compressor.
3.
Vi Load-Unload Timer
This parameter is used to select the period of time that will elapse between the start of pulse signals while
the Vi slide is loading or unloading and the Vi slide position is within the range defined by a set proportional
band. The proximity of the Vi slide to the optimum position determines for which portion of the period the
compressor will be loading. The value is measured in seconds.
Instruction Manual | GEA Omni™
Control panel
Control
Compressor Control Parameters
GEA Refrigeration North America, Inc. | E_806550_2 | Generated 12.01.2016