4.1.7
List and Description of Other Shutdowns
Shutdown
Explanation
Emergency Stop Shutdown
This annunciation will be triggered if the Emergency Stop input becomes de-
energized or the Emergency Stop button is pressed.
Auxiliary Shutdown
This annunciation will be triggered if the Auxiliary Shutdown input becomes
de-energized. This shutdown will only be issued if the Auxiliary Shutdown
option has been enabled in the configuration.
Analog Input Count Mismatch
Shutdown
This annunciation will be triggered if the number of Analog Input slices
detected by the panel is different from the number called for in the configura-
tion.
Analog Output Count Mismatch
Shutdown
This annunciation will be triggered if the number of Analog Output slices
detected by the panel is different from the number called for in the configura-
tion.
Digital Input Count Mismatch
Shutdown
This annunciation will be triggered if the number of Digital Input slices
detected by the panel is different from the number called for in the configura-
tion.
Digital Output Count Mismatch
Shutdown
This annunciation will be triggered if the number of Digital Output slices
detected by the panel is different from the number called for in the configura-
tion.
Analog Slice Not Recognized
Shutdown
This annunciation will be triggered if a slice in the I/O system is not of a type
supported by the GEA Omni Panel.
Sensor Failure Shutdown
This annunciation will be triggered if the reading of a sensor is outside its
defined range. This annunciation will only be triggered if the failed sensor is
critical to the safe operation of the compressor.
Loss of Communications I/O
Network
This annunciation will be triggered if the panel loses its connection to an I/O
Bus Coupler.
Watchdog IO Network
This annunciation will be triggered if the panel is connected properly to an
I/O Bus Coupler, but one or more of the connected slices are not functioning
properly.
4.2
Warnings
Warning annunciations are triggered when a condition occurs that is outside the normal operating conditions of
the system and should be brought to a user’s attention, but is not severe enough that the entire system should
be shut down. All warning annunciations are momentary and will only remain triggered for as long as the condi-
tion that caused them persist.