6.5.3
Troubleshooting
The Session Configuration Tool was checked at the factory during more than
a year for malfunctions and erroneous operations. Hundreds of different con-
figurations were tried, and all sorts of tests have been made. Nevertheless,
since there exists an almost infinite number of channel, bus, and I/O configu-
ration combinations, not all of them could be tested. So it may happen that on
a very rare occasion an error message will be issued during editing or during
the Generate process. A description of some of the typical error messages is
listed below.
6.5.3.1
Errors and Warnings During Generate Process / In Log File
When Inserting a New Function
When inserting a new function that exceeds the capacity of the core, the fol-
lowing dialog will appear:
This message is very likely to appear when the console is operating with
96 kHz, or when switching from 48 to 96 kHz.
If you decide to proceed in generating the configuration regardless of the
warning, the following message will be displayed in the Generate All dialog,
and the configuration process will be stopped.
Could not find pe for ‘Channel Inp Stereo #1 CtrlGrp1’!
Please reduce the requirements of that function
Shared Bus
The load balancing of the on-board communication is not always as accu-
rate as it should be. This may happen because assumptions are made during
load balancing which do not always apply. The following warning will be
displayed in such a case:
Warning: Shared Bus Cycles overflow on board 1, in timeSlot 0.
This does not mean that the configuration does not work. If you want to make
sure that it does work, please send it to the factory for further investigation.
I/O Bus
The I/O bus is a SHARC internal bus used to communicate between the DMA
controller and the internal memory.
Also there assumptions are made which do not always apply. This leads to
the following warning.
Warning: 611 I/O buses of 600 on PE 2 of board 1
Again, this does not mean that the configuration will not work. For further
investigation please send it to the factory.
Vista 5 M3 Digital Mixing System
6-46 Session Configuration
Document generated: 28.08.13
SW V4.9
Summary of Contents for Vista 5 M3
Page 18: ...Vista 5 M3 Digital Mixing System 1 2 Introduction Document generated 28 08 13 SW V4 9 ...
Page 40: ...Vista 5 M3 Digital Mixing System 1 24 Introduction Document generated 28 08 13 SW V4 9 ...
Page 90: ...Vista 5 M3 Digital Mixing System 3 2 Parameters Document generated 28 08 13 SW V4 9 ...
Page 144: ...Vista 5 M3 Digital Mixing System 3 56 Parameters Document generated 28 08 13 SW V4 9 ...
Page 300: ...Vista 5 M3 Digital Mixing System 5 4 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 348: ...Vista 5 M3 Digital Mixing System 5 52 AutoTouchPlus Document generated 28 08 13 SW V4 9 ...
Page 506: ...Vista 5 M3 Digital Mixing System 7 2 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 516: ...Vista 5 M3 Digital Mixing System 7 12 DAW Control Document generated 28 08 13 SW V4 9 ...
Page 518: ...Vista 5 M3 Digital Mixing System 8 2 RELINK Document generated 28 08 13 SW V4 9 ...